SOP: DTI SH85/86 Jointfiler Application
Standard Operating Procedure for using DTI SH85/86 Jointfiler to fill and repair cracks in concrete floors, including preparation, filling, leveling, and cure time requirements.
Product
DTI SH85/86 Jointfiler
Document Type
Standard Operating Procedure
Dwell Time
15 Minutes
Cure Time
3 Hours (no foot traffic)
Application Procedure
- Clean the crack. Use a stiff brush to remove any debris from the crack before applying any product.
- Insert the joint filler. Use the Dual Cartridge Gun with SH85 Joint Fill to insert the filler into the crack.
- Level the filler. Level the filler so it sits flush with the surrounding concrete surface.
- Trim excess material. After 15 minutes, allow the material to sit, then use a trowel or shaving tool to remove any excess.
- Secure the area. Block off the treated area from all foot traffic for at least 3 hours to allow the product to fully cure.
Equipment and Materials
- Stiff brush (for crack preparation)
- Dual Cartridge Gun
- DTI SH85 Joint Fill cartridge
- Trowel or shaving tool
- Perimeter barriers / caution tape
Contact and Support
For product questions or technical support, contact David Phillips:
- Phone: +1-209-407-7523
- Email: [email protected]
- Web: dtindustrialflooring.com
Sources & Standards
Specifications in our guides are based on standards published by these organizations:
- ASTM International — Test methods and standards for concrete surface profiles and coating performance.
- American Concrete Institute (ACI) — Codes and technical guidance for concrete floor design, placement, and repair.
- OSHA — Workplace safety regulations, including walking-working surface and slip-resistance requirements.
- USDA — Sanitation requirements that govern flooring in food processing facilities.
- FDA — Food-contact facility standards referenced in seamless flooring specifications.
- EOS/ESD Association — Publisher of ANSI/ESD S20.20, the standard governing static-control flooring programs.